English Site

9183B

Output Rating
0-35 V, 0-6 A Low Range
0-70 V, 0-3 A High Range
I Number of Channels
210 W Max Output Power
Line Regulation
≤ 0.01 %+1 mV Voltage
≤ 0.01 %+250 uA Current
Line Regulation (1)
≤ 0.01 %+1 mV Voltage
≤ 0.01 %+250 uA Current
Ripple & Noise
≤ 0.5 mVrms /≤5 mVpp Normal Mode Voltage
≤ 2 mA rms Normal Mode Current
≤ 1.5 uA rms Common Mode Current
Programming / Readback Resolution
2 mV Voltage
0.2 mA Current
Programming / Readback Accuracy ± (% output+offset)
≤ 0.05 % +10 mV Voltage
≤ 0.1 % +2 mA Current
Temperature Coefficient per °C ± (% output+offset)
≤ 0.005 %+1 mV Voltage
≤ 0.01 %+3 mA Current
≤ 50 μs for output to recover to within 15 mV Transient Response Time (2)
≤ 30 ms Settling Time (3)
≤ 5 ms Measurement Time
≤ 0.5 %+0.1 V OVP Accuracy
≤ 0.5 %+0.1 A OCP Accuracy
≤ 1 ms OVP/OCP Response Time (4)
≤ 10 ms Rising Time at Full Load / No Load
≤ 10 ms Falling Time at Full Load
≤ 250 ms Falling Time at No Load
Stability (8 hrs) ± (% output+offset)
≤ 0.02 %+2 mV Voltage
0.1 %+1 mA Current
≤ 10 ms (typical) Command Processing Time (5)
Notes:
1 With sense terminal connected.
2 Following a change in output current from full load to half load or vice versa.
3 Maximum time required for the output voltage to change from 1% to 99% or vice versa after receiving a VOLTage or VSET command via GPIB or USB interface.
4 Average time for output to start to drop after OVP/OCP condition occurs.
5 Maximum time for output to change after receipt of commands.
Supplemental Characteristics
8.3” x 5.1” x 16.3”
(210 x 130.5 x 415 mm)
Dimensions (W x H x D)
3U Rack Mount Height
24.2 lbs
(11 kg)
Weight
EN61010-1:2001, EU Low Voltage Directive 2006/95/EC Safety
Meets EMC Directive 2004/108/EC, EN61326-1:2006 Electromagnetic Compatibility
USB Standard Interface
115/230 VAC ± 10%, 47 Hz - 63 Hz AC Input
Environmental
0 °C - 40 °C, < 75% R.H. Operating Temperature
-10 °C - 70 °C, < 85% R.H. Storage Temperature
Three-Year Warranty
User manual, AC power cord, USB cable (type A to type B), line fuse, certificate of calibration and test report Accessories Included
Note: All specifications apply to the unit after a temperature stabilization time of 15 minutes over an ambient temperature range of 23 °C ± 5 °C.

 

The 9170B/9180B series programmable DC power supplies offer industry leading performance, designed to meet the most demanding applications in R&D, design verification, and production test. All nine models deliver clean, stable and precise output power due to their exceptionally low ripple and noise, low temperature coefficient, excellent regulation, and fast transient response time characteristics.
These power supplies are well suited for both bench use and ATE applications. For bench use, these power supplies offer an intuitive user interface with a full numerical keypad for convenient data entry. R&D and design engineers will appreciate front panel output and remote sense terminals (available on select models). Free application software is provided for remote control without the need for any computer programming. USB and optional GPIB/LAN interfaces combined with a fast transient response and command processing time, make this series ideal for ATE applications.
Additionally, this series offers unique features not typically found in other power sources on the market, such as versatile LED test modes, modular interface card slots, automatic range selection, and an optional 8-bit bidirectional digital I/O interface.
To protect your DUT (device under test), the 9170B/9180B series provides safety options such as OVP, OCP, and a key-lock feature to prevent accidental change of parameters that might damage your DUT. Built for reliability, the supplies are also backed by a 3 year warranty.

  • Single and dual output models with up to 210W output power
  • Dual range output with automatic range selection*
  • Programmable voltage and current slew rates
  • Front and rear panel output terminals for convenient wiring
  • Rear panel remote sense terminal (additional front panel remote sense terminal on select single channel models*)
  • List mode for executing up to 10 stored test sequences with a maximum of 150 steps in total
  • Store and recall up to 10 power settings
  • SCPI compliant USB standard interface, RS232, GPIB & LAN, RS485 optional (Installation through modular interface slots)
  • Exceptionally fast command processing time, less than 10 ms, greatly reduces overall test time
  • Remote analog programming interface (option)
  • Unique LED test modes for minimizing inrush current
  • Application software for remote control
  • Overvoltage (OVP) and overcurrent (OCP) protection, including key-lock function
  • Convenient voltage and current calibration via front panel
  • LabVIEWTM drivers available for download
* Except for high voltage models 9184B and 9185B.